在 iX6580 的中英版维修手册中需要修正如下错误。
修正:
1-1. Troubleshooting by Symptom
根据现象判断故障并解决
Symptom: | Graphic or text is enlarged on printouts in the paper feed direction. |
现象: | 图像或文档在输出方向被放大打印。 |
Solution: 解决方法: |
Wrong | Correct |
(1) Confirm that the LF slit film is free from smearing or scratches: - Cleaning of the LF slit film. (2) Replace the following item(s): - Timing slit disk feed film - Timing slit disk eject film - Timing sensor unit - Platen unit - Logic board ass'y | (1) Confirm that the LF slit film is free from smearing or scratches: - Cleaning of the LF slit film. (2) Replace the following item(s): - Timing slit disk feed film - Timing slit disk eject film - 定时出纸盘型编码器 - Timing sensor unit - Platen unit - Logic board ass'y |
QN-12C-0168
April 28, 2011
维 修 信 息
Canon CCN CSP S&S TS 发布